SAV-200, 250, 300 hp
(Electra Saver Series)

Features:
Direct Drive,
Turn Valve part load control
Large, Slow Speed Air Ends
"ES+" Series Controller
745 - 1500 CFM, 100-150 p.s.i.

Standard Equipment:
  • Direct drive, non-geared, C-flange mounted airend.
  • Automatic, integral Turn Valve part-load control system.
  • Heavy-duty, 5 micron, dry canister-type, inlet air filter.
  • 230 or 460/3/60 1.15 SF, ODP, EPAct "energy efficient" drive motor. 1800 or 3600 RPM.
  • Airend and motor shaft are coupled through a permanently aligned, resilient, cushion-type, flexible coupling.
  • Stainless steel control lines.
  • Unitized airend/motor assembly mounted to the compressor base with all angle elastomer vibration isolators.
  • ASME coded air/oil reservoir with Eliminator separator element.
  • Air or Water cooled Oil cooler/after cooler.
  • Air cooled models have a heavy duty radiator type heat exchanger with a thermally controlled, totally enclosed fan motor.
  • Water cooled models have a shell and tube type heat exchanger.
  • Thermostatic oil control valve.
  • Package mounted moisture separator and trap.
  • Rigid steel base with fork lift slots.
  • Pressure relief valve and discharge check valve.
  • Automatic blow down valve through inlet filter.
  • Minimum discharge pressure valve.
  • Lube system includes all galvanized steel fittings and piping.
  • Factory fill with AEON 9000 Rotary Screw Lubricant.
  • Modulating capacity control system with automatic "low demand" mode reservoir blow down.
  • Auto Sentry "ES+"microprocessor based, fully programmable, touch pad controller with the following functions:
  • Full text vacuum florescent display (VFD) with interactive compressor diagram.
    • Operating mode selection: constant run, low demand with reservoir blow down, automatic stop/start with timed blow down and sequence (up to 8 units), all with modulating inlet valve or load/no lode control.
    • Emergency stop button.
    • Power interruption protection.
    • High speed electronic modulation control
    • Thermally controlled fan motor on air cooled units.
    • Contacts for remote start/stop operation plus remote monitoring
    • Complete system diagnostics through VFD.
    • Displays for hour meter, loaded hours, total run time, discharge air temperature, system/reservoir pressure, separator differential pressure and motor amps.
    • VFD advisory lamps, light yellow on diagram, displays service for air filter, change separator, oil and oil filter change, high/low temperature, sequencing communication error, and high motor amps.
    • VFD protective shut down lamps, light red on diagram, displays high temperature, low oil pressure, main motor overload, fan motor overload, high pressure, change separator, choice of one field-selectable message:
    • High vibration, phase relay, motor protector, low voltage.