Standard Equipment:
- Direct drive, non-geared, C-flange mounted airend.
- Automatic, integral Turn Valve part-load control system.
- Heavy-duty, 5 micron, dry canister-type, inlet air filter.
- 230 or 460/3/60 1.15 SF, ODP, EPAct "energy efficient"
drive motor. 1800 or 3600 RPM.
- Airend and motor shaft are coupled through a permanently aligned,
resilient, cushion-type, flexible coupling.
- Stainless steel control lines.
- Unitized airend/motor assembly mounted to the compressor base
with all angle elastomer vibration isolators.
- ASME coded air/oil reservoir with Eliminator separator element.
- Air or Water cooled Oil cooler/after cooler.
- Air cooled models have a heavy duty radiator type heat exchanger
with a thermally controlled, totally enclosed fan motor.
- Water cooled models have a shell and tube type heat exchanger.
- Thermostatic oil control valve.
- Package mounted moisture separator and trap.
- Rigid steel base with fork lift slots.
- Pressure relief valve and discharge check valve.
- Automatic blow down valve through inlet filter.
- Minimum discharge pressure valve.
- Lube system includes all galvanized steel fittings and piping.
- Factory fill with AEON 9000 Rotary Screw Lubricant.
- Modulating capacity control system with automatic "low demand"
mode reservoir blow down.
- Auto Sentry "ES+"microprocessor based, fully programmable,
touch pad controller with the following functions:
- Full text vacuum florescent display (VFD) with interactive
compressor diagram.
- Operating mode selection: constant run, low demand with reservoir
blow down, automatic stop/start with timed blow down and sequence (up to 8 units),
all with modulating inlet valve or load/no lode control.
- Emergency stop button.
- Power interruption protection.
- High speed electronic modulation control
- Thermally controlled fan motor on air cooled units.
- Contacts for remote start/stop operation plus remote monitoring
- Complete system diagnostics through VFD.
- Displays for hour meter, loaded hours, total run time, discharge
air temperature, system/reservoir pressure, separator differential pressure and
motor amps.
- VFD advisory lamps, light yellow on diagram, displays service
for air filter, change separator, oil and oil filter change, high/low temperature,
sequencing communication error, and high motor amps.
- VFD protective shut down lamps, light red on diagram, displays
high temperature, low oil pressure, main motor overload, fan motor overload, high
pressure, change separator, choice of one field-selectable message:
- High vibration, phase relay, motor protector, low voltage.
|
|