header_concept

Back


ST-125, 150, 200 hp
(Electra Saver II Series)
Features:
Direct Drive
Slow Speed, Large Air Ends
"ES+" Series Controller
540 - 760 CFM, 100-150 p.s.i.
Model EBQ
ST-125
Pressure
CFM
BHP
100
630
134
110*
-
-
125
540
130
* 110 p.s.i. is a field set option only
Dimensions
114" x 68" x 69" (L x W x H)
Shipping Weight
4,800 lbs, (5,500 enclosed)
Model EGP
125 DX
Pressure
CFM
BHP
100
490
106
110
488
111
125
485
119
150
480
132
Dimensions
114" x 68" x 69" (L x W x H)
Shipping Weight
4,800 lbs, (5,500 enclosed)
Model EBQ
ST-150
Pressure
CFM
BHP
100
760
161
110
757
169
125
620
150
150
530
145
Dimensions
114" x 68" x 69" (L x W x H)
Shipping Weight
4,800 lbs, (5,500 enclosed)
Model EGQ
ST-200DX
Pressure
CFM
BHP
100
760
161
110
757
169
125
752
181
150
745
201
Dimensions
114" x 68" x 69" (L x W x H)
Shipping Weight
5,598lbs, (6,360 enclosed)
Model EBU
ST-200
Pressure
CFM
BHP
100
1030
220
110*
-
-
125
920
217
* 110 p.s.i. is a field set option only
Dimensions
114" x 68" x 69" (L x W x H)
Shipping Weight
5,050 lbs, (5,650 enclosed)

Standard Equipment:
  • Direct drive, non-geared, D-flange mounted airend.
  • Modulating, vertical inlet valve.
  • Heavy-duty, 5 micron, dry canister-type, inlet air filter.
  • 230 or 460/3/60 1.15 SF, ODP, EPAct "energy efficient" drive motor. 1800 or 3600 RPM.
  • DX models include a 125 or 200 hp oversized drive motor designed not to run into the service factor at 100/125 p.s.i.
  • Airend and motor shaft are coupled through a permanently aligned, resilient, cushion-type, flexible coupling.
  • Stainless steel control lines.
  • Unitized airend/motor assembly mounted to the compressor base with all angle elastomer vibration isolators.
  • ASME coded air/oil reservoir with
  • Eliminator separator element.
  • Air or Water cooled - Oil cooler/after cooler.
  • Air cooled models have a heavy duty radiator type heat exchanger with a thermally controlled, totally enclosed fan motor.
  • Water cooled models have a shell and tube type heat exchanger.
  • Thermostatic oil mixing valve.
  • Package mounted moisture separator and trap.
  • Rigid steel base with fork lift slots.
  • Pressure relief valve and discharge check valve.
  • Automatic blow down valve through inlet filter.
  • Minimum discharge pressure valve.
  • Lube system includes all galvanized steel fittings and piping.
  • Factories fill with AEON 9000 Rotary
  • Screw Lubricant.
  • NEMA 12 control/electrical enclosure include UL listed and CSA certified electrics.
  • Auto Sentry "ES+"microprocessor based, fully programmable, touch pad controller with the following functions:
  • <
  • Full text vacuum florescent display (VFD) with interactive compressor diagram.
  • Operating mode selection: constant run, low demand with reservoir blow down, automatic stop/start with timed blow down and sequence (up to 8 units), all with modulating inlet valve or load/no lode control.
  • Emergency stop button.
  • Power interruption protection.
  • High speed electronic modulation control
  • Thermally controlled fan motor on air cooled units.
  • Contacts for remote start/stop operation plus remote monitoring
  • Complete system diagnostics through VFD.
    • Displays for hour meter, loaded hours, total run time, discharge air temperature, system/reservoir pressure, separator differential pressure and motor amps.
    • VFD advisory lamps, light yellow on diagram, displays service for air filter, change separator, oil and oil filter change, high/low temperature, sequencing communication error, and high motor amps.
    • VFD protective shut down lamps, light red on diagram, displays high temperature, low oil pressure, main motor overload, fan motor overload, high pressure, change separator, choice of one field-selectable message: High vibration, phase relay, motor protector, and low voltage.
  • Optional Equipment:
    • Wye delta main motor and starter - IEC rated.
    • NEMA 4 (IP-66) control enclosure.
    • TEFC and premium efficiency main motor.
    • Sound attenuating full enclosure.
    • Remote mounted after cooler and oil cooler for air cooled models.
    • Seacoast (air-cooled) or saltwater (water-coooled) after cooler and heat exchangers.
    • Factory fill AEON 6000FG food grade lubricant.